R452A Opteon™ XP44 HFO Refrigerant
R452A, also known as Opteon™ XP44, is a lower-GWP HFO refrigerant blend used as a replacement for R404A and R507 in low-temperature transport refrigeration applications.
Designed to closely match the performance of R404A, R452A is suitable for transport refrigeration systems where low discharge temperatures are required. As a zeotropic blend containing R32, R125 and R1234yf, R452A must be charged from the liquid phase to maintain accurate refrigerant composition during service and installation.
Key Features
R452A refrigerant
Also known as Opteon™ XP44
Lower-GWP HFO refrigerant blend
Replacement for R404A and R507 in suitable systems
Suitable for low-temperature transport refrigeration applications
Alternative to R404A series low and medium-temperature refrigerants
Performance closely matches R404A
Zeotropic blend containing R32, R125 and R1234yf
Must be charged from the liquid phase
Non-flammable refrigerant
A1 safety classification
Requires polyolester oil in the compressor
Suitable for retrofit or new installations where compatible
For use where low discharge temperatures are required
A-Gas cylinders include dual port valves for easier liquid offtake
A-Gas product cylinders are fitted with a Residual Pressure Device
A-Gas operates a returnable cylinder fleet
Specifications
| Specification | Details |
|---|
| Product | R452A |
| Trade Name | Opteon™ XP44 |
| Brand | A-Gas |
| Refrigerant Type | HFO Blend |
| Blend Type | Zeotropic |
| Components | R32, R125 and R1234yf |
| Common Replacements | R404A and R507 in suitable systems |
| Primary Use | Low-temperature transport refrigeration |
| Additional Use | Alternative to R404A series low and medium-temperature refrigerants |
| Safety Classification | A1 |
| Flammability | Non-flammable |
| Charging Requirement | Charge from liquid phase |
| Oil Requirement | Polyolester oil |
| Retrofit Suitability | Suitable for retrofit or new installations where compatible |
| Cylinder Feature | Dual port valves for easier liquid offtake |
| Cylinder Safety Feature | Residual Pressure Device |
| Cylinder Program | Returnable cylinder fleet |
| Storage Requirement | Cool, dry, well-ventilated area out of direct sunlight |
| Recommended Category | Refrigeration > Refrigeration Components > Refrigerants |
Applications
Transport refrigeration
Low-temperature transport refrigeration systems
Suitable R404A replacement applications
Suitable R507 replacement applications
R404A series low and medium-temperature replacement applications
New compatible refrigeration installations
Existing compatible retrofit applications
Systems where low discharge temperatures are required
Safety & Documentation
R452A must be handled by appropriately licensed refrigeration and air-conditioning technicians. As a zeotropic refrigerant blend, it must be charged from the liquid phase to maintain accurate composition during installation and service.
A-Gas notes that compressors must be charged with polyolester oils, and technicians should contact the compressor manufacturer for system-specific oil compatibility guidance. Store cylinders in a cool, dry and well-ventilated area, away from direct sunlight. Used cylinders should be returned through the A-Gas wholesale partner returnable cylinder fleet.
Always refer to the current A-Gas Safety Data Sheet and equipment manufacturer guidance before use.
A-Gas R452A Opteon™ XP44 is a practical lower-GWP refrigerant option for compatible transport refrigeration systems where a non-flammable A1 replacement for R404A or R507 is required.