Hisense AKT-35UR4RK8 3.5kW Multi-Split Floor Console Indoor Unit
The Hisense AKT-35UR4RK8 is a compact floor-mounted console designed for connection to a compatible Hisense multi-split outdoor unit. Its low-wall format is ideal for rooms where conventional high-wall installation is impractical, including spaces with sloping ceilings, limited wall area or large windows.
Independent upper and lower air outlets provide flexible airflow distribution. In heating mode, Bottom Hot Air can discharge warm air near floor level, producing a comfortable floor-up heating effect and helping reduce warm-air stratification.
Key Features
3.5kW cooling and 4.0kW heating capacity
Independent dual-vane airflow control
Upper and lower air discharge
Bottom Hot Air heating mode
Multiple selectable airflow patterns
Hidden LED temperature display
Temperature adjustment in 0.5°C increments
Display readings accurate to 0.1°C
Real-time room humidity display in Dry mode
Flexible refrigerant and drainage connections
Suitable for surface, corner or partially recessed installation
Compact 220mm-deep cabinet
Compatible with Hisense multi-split systems
Specifications
| Specification | Details |
|---|
| Model | AKT-35UR4RK8 |
| Unit type | Multi-split floor console indoor unit |
| Cooling capacity | 3.5kW |
| Heating capacity | 4.0kW |
| Airflow range | 440–600m³/h |
| Sound pressure level | 33–40dB(A) |
| Sound power level | 56dB(A) |
| Indoor unit dimensions | 700 × 630 × 220mm |
| Indoor unit weight | 15kg |
| Liquid pipe connection | 6.35mm (1/4″) |
| Gas pipe connection | 9.53mm (3/8″) |
| Refrigerant | R32 |
| Power supply | 220–240V, 50Hz |
The AKT-35UR4RK8 is an indoor unit only and requires connection to a compatible Hisense multi-split outdoor unit.
Source: Hisense Australia.
Dual Vane Design
The unique dual vane can be completely sealed when the unit is off, and can rotate independently when the unit is on. The console unit can give a comfortable airflow distribution depending on the user's needs.
Various Airflow
Various Airflow is a great solution to activate different airflow modes for different users' preferences. For example for heating, the unit can be set to Bottom Hot Air, instead of top air-out. In Bottom Hot Air, the hot airflow blows from the bottom air outlet, giving a more effective heating feeling, from your feet upwards.
Hidden Display
The LED hidden display provides precise feedback, with temperature control accurate to 0.5 °C and display readings to 0.1 °C. In Dry Mode, the unit also shows real-time room humidity.
Hidden Installation
For added flexibility on special projects, the console unit can be discreetly installed in a corner or recessed into a wall cavity. This hidden installation option helps the unit blend seamlessly with the interior design, reducing visual impact while maintaining full performance.
Flexible Piping
For maximum installation flexibility, both the refrigerant and drainage pipes can be connected from any direction, including all sides of the unit. This versatile design makes installation easier in tight spaces and allows technicians to adapt to different room layouts without compromise.